VeriPHY Cable Diagnostic is a function of VigorSwitch that helps the network administrator to monitor the physical status of the cable.
The pair is the twisted pair of Ethernet cable, and each pair corresponds to a set of pins.
|
Pair |
Pins |
Function |
|
A |
1 and 2 |
This pair controls whether or not the port should go up or down |
|
B |
3 and 6 |
Protocol-level and controls FastEthernet |
|
C |
4 and 5 |
Power over Ethernet (PoE) |
|
D |
7 and 8 |
GigabitEthernet |
Depends on the status of each line pair, there are different meaning of length.
|
Status |
Description |
Meaning of Length |
|
OK |
Good cable, good pair |
The length of the cable (Note that the length is only accurate for cables of length 7m to 140m) |
|
Open |
An opening is detected on the cable |
The position of the opening |
|
Abnormal |
The impedance is not within the expected bounds, either too high or too low |
The position of the abnormal impedance |
|
Short |
A short is detected on the cable. cable length is shorter than 7m |
The position of the short |
|
Cross |
Abnormal cross-pair coupling in pair |
The position of the cross-pair coupling |
Published On:2015-11-20
ShareWas this helpful?